Disabled: pcntl_alarm,pcntl_fork,pcntl_waitpid,pcntl_wait,pcntl_wifexited,pcntl_wifstopped,pcntl_wifsignaled,pcntl_wifcontinued,pcntl_wexitstatus,pcntl_wtermsig,pcntl_wstopsig,pcntl_signal,pcntl_signal_get_handler,pcntl_signal_dispatch,pcntl_get_last_error,pcntl_strerror,pcntl_sigprocmask,pcntl_sigwaitinfo,pcntl_sigtimedwait,pcntl_exec,pcntl_getpriority,pcntl_setpriority,pcntl_async_signals,pcntl_unshare,
Upload Files
File: //var/lib/mibs/ietf/IPFIX-MIB
IPFIX-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE, mib-2, Unsigned32, Counter64,
    Gauge32
        FROM SNMPv2-SMI                                -- RFC2578
    TimeStamp, DateAndTime
        FROM SNMPv2-TC                                 -- RFC2579
    MODULE-COMPLIANCE, OBJECT-GROUP
        FROM SNMPv2-CONF                               -- RFC2580
    InterfaceIndexOrZero
        FROM IF-MIB                                    -- RFC2863
    InetAddressType, InetAddress, InetPortNumber
        FROM INET-ADDRESS-MIB                          -- RFC4001
    PhysicalIndexOrZero
        FROM ENTITY-MIB;                               -- RFC4133

ipfixMIB MODULE-IDENTITY
    LAST-UPDATED "201004190000Z"         -- 19 April 2010
    ORGANIZATION "IETF IPFIX Working Group"
    CONTACT-INFO
        "WG charter:
          http://www.ietf.org/html.charters/ipfix-charter.html

        Mailing Lists:
          General Discussion: ipfix@ietf.org
          To Subscribe: http://www1.ietf.org/mailman/listinfo/ipfix
          Archive:
      http://www1.ietf.org/mail-archive/web/ipfix/current/index.html

        Editor:
          Thomas Dietz
          NEC Europe Ltd.
          NEC Laboratories Europe
          Network Research Division
          Kurfuersten-Anlage 36
          69115 Heidelberg
          Germany
          Phone: +49 6221 4342-128
          Email: Thomas.Dietz@nw.neclab.eu

          Atsushi Kobayashi
          NTT Information Sharing Platform Laboratories
          3-9-11 Midori-cho
          Musashino-shi
          180-8585
          Japan
          Phone: +81-422-59-3978
          Email: akoba@nttv6.net

          Benoit Claise
          Cisco Systems, Inc.
          De Kleetlaan 6a b1
          Degem 1831
          Belgium
          Phone:  +32 2 704 5622
          Email: bclaise@cisco.com

          Gerhard Muenz
          Technische Universitaet Muenchen
          Department of Informatics
          Chair for Network Architectures and Services (I8)
          Boltzmannstr. 3
          85748 Garching
          Germany
          Phone: +49 89 289-18008
          Email: muenz@net.in.tum.de
          URI:   http://www.net.in.tum.de/~muenz"
    DESCRIPTION
        "The IPFIX MIB defines managed objects for IP Flow
        Information eXport.  These objects provide information about
        managed nodes supporting the IPFIX protocol,
        for Exporters as well as for Collectors.

        Copyright (c) 2010 IETF Trust and the persons identified as
        authors of the code.  All rights reserved.

        Redistribution and use in source and binary forms, with or
        without modification, is permitted pursuant to, and subject
        to the license terms contained in, the Simplified BSD
        License set forth in Section 4.c of the IETF Trust's
        Legal Provisions Relating to IETF Documents
        (http://trustee.ietf.org/license-info)."

--  Revision history

     REVISION     "201004190000Z"         -- 19 April 2010
     DESCRIPTION
        "Initial version, published as RFC 5815."
    ::= { mib-2 193 }

--******************************************************************
-- Top Level Structure of the MIB
--******************************************************************

ipfixObjects     OBJECT IDENTIFIER ::= { ipfixMIB 1 }
ipfixConformance OBJECT IDENTIFIER ::= { ipfixMIB 2 }

ipfixMainObjects OBJECT IDENTIFIER ::= { ipfixObjects 1 }
ipfixStatistics  OBJECT IDENTIFIER ::= { ipfixObjects 2 }

--==================================================================
-- 1.1: Objects used by all IPFIX implementations
--==================================================================
--------------------------------------------------------------------
-- 1.1.1: Transport Session Table
--------------------------------------------------------------------
ipfixTransportSessionTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF IpfixTransportSessionEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table lists the currently established Transport
        Sessions between an Exporting Process and a Collecting
        Process."
    ::= { ipfixMainObjects 1 }

ipfixTransportSessionEntry OBJECT-TYPE
    SYNTAX      IpfixTransportSessionEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Defines an entry in the ipfixTransportSessionTable."
    INDEX       { ipfixTransportSessionIndex }
    ::= { ipfixTransportSessionTable 1 }

IpfixTransportSessionEntry ::=
    SEQUENCE {
       ipfixTransportSessionIndex                  Unsigned32,
       ipfixTransportSessionProtocol               Unsigned32,
       ipfixTransportSessionSourceAddressType      InetAddressType,
       ipfixTransportSessionSourceAddress          InetAddress,
       ipfixTransportSessionDestinationAddressType InetAddressType,
       ipfixTransportSessionDestinationAddress     InetAddress,
       ipfixTransportSessionSourcePort             InetPortNumber,
       ipfixTransportSessionDestinationPort        InetPortNumber,
       ipfixTransportSessionSctpAssocId            Unsigned32,
       ipfixTransportSessionDeviceMode             INTEGER,
       ipfixTransportSessionTemplateRefreshTimeout Unsigned32,
       ipfixTransportSessionOptionsTemplateRefreshTimeout Unsigned32,
       ipfixTransportSessionTemplateRefreshPacket  Unsigned32,
       ipfixTransportSessionOptionsTemplateRefreshPacket Unsigned32,
       ipfixTransportSessionIpfixVersion           Unsigned32,
       ipfixTransportSessionStatus                 INTEGER
    }

ipfixTransportSessionIndex OBJECT-TYPE
    SYNTAX      Unsigned32 (1..4294967295)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Locally arbitrary, but unique identifier of an entry in
        the ipfixTransportSessionTable.  The value is expected to
        remain constant from a re-initialization of the entity's
        network management agent to the next re-initialization."
    ::= { ipfixTransportSessionEntry 1 }

ipfixTransportSessionProtocol OBJECT-TYPE
    SYNTAX      Unsigned32 (1..255)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The transport protocol used for receiving or transmitting
        IPFIX Messages.  Protocol numbers are assigned by IANA.  A
        current list of all assignments is available from
        <http://www.iana.org/>."
    REFERENCE
        "RFC 5101, Specification of the IP Flow
        Information Export (IPFIX) Protocol for the Exchange of IP
        Traffic Flow Information, Section 10."
    ::= { ipfixTransportSessionEntry 2 }

ipfixTransportSessionSourceAddressType OBJECT-TYPE
    SYNTAX      InetAddressType
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The type of address used for the source address,
        as specified in RFC 4001.  This object is used with protocols
        (specified in ipfixTransportSessionProtocol) like TCP (6)
        and UDP (17) that have the notion of addresses.  SCTP (132)
        should use the ipfixTransportSessionSctpAssocId instead.
        If SCTP (132) or any other protocol without the notion of
        addresses is used, the object MUST be set to unknown(0)."
    ::= { ipfixTransportSessionEntry 3 }

ipfixTransportSessionSourceAddress OBJECT-TYPE
    SYNTAX      InetAddress
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The source address of the Exporter of the IPFIX Transport
        Session.  This value is interpreted according to the value of
        ipfixTransportSessionAddressType as specified in RFC 4001.
        This object is used with protocols (specified in
        ipfixTransportSessionProtocol) like TCP (6) and UDP (17) that
        have the notion of addresses.  SCTP (132) should use the
        ipfixTransportSessionSctpAssocId instead.  If SCTP (132) or
        any other protocol without the notion of addresses is used,
        the object MUST be set to a zero-length string."
    ::= { ipfixTransportSessionEntry 4 }

ipfixTransportSessionDestinationAddressType OBJECT-TYPE
    SYNTAX      InetAddressType
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The type of address used for the destination address,
        as specified in RFC 4001.  This object is used with protocols
        (specified in ipfixTransportSessionProtocol) like TCP (6)
        and UDP (17) that have the notion of addresses.  SCTP (132)
        should use the ipfixTransportSessionSctpAssocId instead.
        If SCTP (132) or any other protocol without the notion of
        addresses is used, the object MUST be set to unknown(0)."
    ::= { ipfixTransportSessionEntry 5 }

ipfixTransportSessionDestinationAddress OBJECT-TYPE
    SYNTAX      InetAddress
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The destination address of the Collector of the IPFIX
        Transport Session.  This value is interpreted according to
        the value of ipfixTransportSessionAddressType, as specified
        in RFC 4001.  This object is used with protocols
        (specified in ipfixTransportSessionProtocol) like TCP (6)
        and UDP (17) that have the notion of addresses.  SCTP (132)
        should use the ipfixTransportSessionSctpAssocId instead.
        If SCTP (132) or any other protocol without the notion of
        addresses is used, the object MUST be set to a zero-length
        string"
    ::= { ipfixTransportSessionEntry 6 }

ipfixTransportSessionSourcePort OBJECT-TYPE
    SYNTAX      InetPortNumber
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The transport protocol port number of the Exporter.
        This object is used with protocols (specified in
        ipfixTransportSessionProtocol) like TCP (6)
        and UDP (17) that have the notion of ports.  SCTP (132)
        should copy the value of sctpAssocLocalPort if the
        Transport Session is in collecting mode or
        sctpAssocRemPort if the Transport Session is in
        exporting mode.  The association is referenced
        by the ipfixTransportSessionSctpAssocId.
        If any other protocol without the notion of
        ports is used, the object MUST be set to zero."
    ::= { ipfixTransportSessionEntry 7 }

ipfixTransportSessionDestinationPort OBJECT-TYPE
    SYNTAX      InetPortNumber
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The transport protocol port number of the Collector.  The
        default value is 4739 for all currently defined transport
        protocol types.  This object is used with protocols
        (specified in ipfixTransportSessionProtocol) like TCP (6)
        and UDP (17) that have the notion of ports.  SCTP (132)
        should copy the value of sctpAssocRemPort if the
        Transport Session is in collecting mode or
        sctpAssocLocalPort if the Transport Session is in
        exporting mode.  The association is referenced
        by the ipfixTransportSessionSctpAssocId.
        If any other protocol without the notion of
        ports is used, the object MUST be set to zero."
    ::= { ipfixTransportSessionEntry 8 }

ipfixTransportSessionSctpAssocId OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The association id used for the SCTP session between the
        Exporter and the Collector of the IPFIX Transport Session.
        It is equal to the sctpAssocId entry in the sctpAssocTable
        defined in the SCTP MIB.  This object is only valid if
        ipfixTransportSessionProtocol has the value 132 (SCTP).  In
        all other cases, the value MUST be zero."
    REFERENCE
        "RFC 3873, Stream Control Transmission Protocol (SCTP)
        Management Information Base (MIB)."
    ::= { ipfixTransportSessionEntry 9 }

ipfixTransportSessionDeviceMode OBJECT-TYPE
    SYNTAX      INTEGER {
                    exporting(1),
                    collecting(2)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The mode of operation of the device for the given Transport
        Session.  This object can have the following values:

        exporting(1)
            This value MUST be used if the Transport Session is
            used for exporting Records to other IPFIX Devices,
            i.e., this device acts as Exporter.

        collecting(2)
            This value MUST be used if the Transport Session is
            used for collecting Records from other IPFIX Devices,
            i.e., this device acts as Collector."
    ::= { ipfixTransportSessionEntry 10 }

ipfixTransportSessionTemplateRefreshTimeout OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "On Exporters, this object contains the time in seconds
        after which IPFIX Templates are resent by the
        Exporter.

        On Collectors, this object contains the lifetime in seconds
        after which a Template becomes invalid when it is not
        received again within this lifetime.

        This object is only valid if ipfixTransportSessionProtocol
        has the value 17 (UDP).  In all other cases, the value MUST
        be zero."
    REFERENCE
        "RFC 5101, Specification of the IP Flow Information Export
        (IPFIX) Protocol for the Exchange of IP Traffic Flow
        Information, Sections 10.3.6 and 10.3.7."
    ::= { ipfixTransportSessionEntry 11 }

ipfixTransportSessionOptionsTemplateRefreshTimeout OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "On Exporters, this object contains the time in seconds
        after which IPFIX Options Templates are resent by the
        Exporter.

        On Collectors, this object contains the lifetime in seconds
        after which an Options Template becomes invalid when it is
        not received again within this lifetime.

        This object is only valid if ipfixTransportSessionProtocol
        has the value 17 (UDP).  In all other cases the value MUST
        be zero."
    REFERENCE
        "RFC 5101, Specification of the IP Flow Information Export
        (IPFIX) Protocol for the Exchange of IP Traffic Flow
        Information, Sections 10.3.6 and 10.3.7."
    ::= { ipfixTransportSessionEntry 12 }

ipfixTransportSessionTemplateRefreshPacket OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "packets"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "On Exporters, this object contains the number of exported
        IPFIX Messages after which IPFIX Templates are resent
        by the Exporter.

        On Collectors, this object contains the lifetime in number
        of exported IPFIX Messages after which a Template becomes
        invalid when it is not received again within this lifetime.

        This object is only valid if ipfixTransportSessionProtocol
        has the value 17 (UDP).  In all other cases the value MUST
        be zero."
    REFERENCE
        "RFC 5101, Specification of the IP Flow Information Export
        (IPFIX) Protocol for the Exchange of IP Traffic Flow
        Information, Sections 10.3.6 and 10.3.7."
    ::= { ipfixTransportSessionEntry 13 }

ipfixTransportSessionOptionsTemplateRefreshPacket OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "packets"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "On Exporters, this object contains the number of exported
        IPFIX Messages after which IPFIX Options Templates are
        resent by the Exporter.

        On Collectors, this object contains the lifetime in number
        of exported IPFIX Messages after which an Options Template
        becomes invalid when it is not received again within this
        lifetime.

        This object is only valid if ipfixTransportSessionProtocol
        has the value 17 (UDP).  In all other cases the value MUST
        be zero."
    REFERENCE
        "RFC 5101, Specification of the IP Flow Information Export
        (IPFIX) Protocol for the Exchange of IP Traffic Flow
        Information, Sections 10.3.6 and 10.3.7."
    ::= { ipfixTransportSessionEntry 14 }

ipfixTransportSessionIpfixVersion OBJECT-TYPE
    SYNTAX      Unsigned32 (0..65535)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "On Exporters the object contains the version number of the
        IPFIX protocol that the Exporter uses to export its data in
        this Transport Session.

        On Collectors the object contains the version number of the
        IPFIX protocol it receives for this Transport Session.

        If IPFIX Messages of different IPFIX protocol versions are
        transmitted or received in this Transport Session, this
        object contains the maximum version number."
    REFERENCE
        "RFC 5101, Specification of the IP Flow Information Export
        (IPFIX) Protocol for the Exchange of IP Traffic Flow
        Information, Section 3.1."
    ::= { ipfixTransportSessionEntry 15 }

ipfixTransportSessionStatus OBJECT-TYPE
    SYNTAX      INTEGER {
                    unknown(0),
                    inactive(1),
                    active(2)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The status of a Transport Session.  This object can have the
        following values:

        unknown(0)
            This value MUST be used if the status of the
            Transport Session cannot be detected by the equipment.
            This value should be avoided as far as possible.

        inactive(1)
            This value MUST be used for Transport Sessions that
            are specified in the system but are not currently active.
            The value can be used, e.g., for Transport Sessions that
            are backup (secondary) sessions in a Transport Session
            group.

        active(2)
            This value MUST be used for Transport Sessions that are
            currently active and transmitting or receiving data."
    ::= { ipfixTransportSessionEntry 16 }

--------------------------------------------------------------------
-- 1.1.2: Template Table
--------------------------------------------------------------------
ipfixTemplateTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF IpfixTemplateEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table lists the Templates and Options Templates that
        are transmitted by the Exporting Process or received by the
        Collecting Process.

        The table contains the Templates and Options Templates that
        are received or used for exporting data for a given
        Transport Session group and Observation Domain.

        Withdrawn or invalidated (Options) Template MUST be removed
        from this table."
    ::= { ipfixMainObjects 2 }

ipfixTemplateEntry OBJECT-TYPE
    SYNTAX      IpfixTemplateEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Defines an entry in the ipfixTemplateTable."
    INDEX       {
        ipfixTransportSessionIndex,
        ipfixTemplateObservationDomainId,
        ipfixTemplateId
    }
    ::= { ipfixTemplateTable 1 }

IpfixTemplateEntry ::=
    SEQUENCE {
        ipfixTemplateObservationDomainId Unsigned32,
        ipfixTemplateId                  Unsigned32,
        ipfixTemplateSetId               Unsigned32,
        ipfixTemplateAccessTime          DateAndTime
    }

ipfixTemplateObservationDomainId OBJECT-TYPE
    SYNTAX      Unsigned32 (0..4294967295)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The Id of the Observation Domain for which this Template
        is defined.  This value is used when sending IPFIX Messages.

        The special value of 0 indicates that the Data Records
        exported with this (Option Template) cannot be applied to a
        single Observation Domain."
    REFERENCE
        "RFC 5101, Specification of the IP Flow Information Export
        (IPFIX) Protocol for the Exchange of IP Traffic Flow
        Information, Section 3.1."
    ::= { ipfixTemplateEntry 1 }

ipfixTemplateId OBJECT-TYPE
    SYNTAX      Unsigned32 (256..65535)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This number indicates the Template Id in the IPFIX
        Message.  Values from 0 to 255 are not allowed for Template
        Ids."
    REFERENCE
        "RFC 5101, Specification of the IP Flow Information Export
        (IPFIX) Protocol for the Exchange of IP Traffic Flow
        Information, Section 3.4.1."
    ::= { ipfixTemplateEntry 2 }

ipfixTemplateSetId OBJECT-TYPE
    SYNTAX      Unsigned32 (1..65535)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This number indicates the Set Id of the Template.  This
        object allows to easily retrieve the Template type.

        Currently, there are two values defined.  The value 2 is
        used for Sets containing Template definitions.  The value 3
        is used for Sets containing Options Template definitions."
    REFERENCE
        "RFC 5101, Specification of the IP Flow Information Export
        (IPFIX) Protocol for the Exchange of IP Traffic Flow
        Information, Section 3.3.2."
    ::= { ipfixTemplateEntry 3 }

ipfixTemplateAccessTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "If the Transport Session is in exporting mode
        (ipfixTransportSessionDeviceMode) the time when this
        (Options) Template was last sent to the Collector(s).

        In the specific case of UDP as transport protocol, this
        time is used to know when a retransmission of the
        (Options) Template is needed.

        If it is in collecting mode, this object contains the
        time when this (Options) Template was last received from
        the Exporter.  In the specific case of UDP as transport
        protocol, this time is used to know when this (Options)
        Template times out and thus is no longer valid."
    ::= { ipfixTemplateEntry 4 }

--------------------------------------------------------------------
-- 1.1.3: Exported Template Definition Table
--------------------------------------------------------------------
ipfixTemplateDefinitionTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF IpfixTemplateDefinitionEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "On Exporters, this table lists the (Options) Template fields
        of which a (Options) Template is defined.  It defines the
        (Options) Template given in the ipfixTemplateId specified in
        the ipfixTemplateTable.

        On Collectors, this table lists the (Options) Template fields
        of which a (Options) Template is defined.  It defines the
        (Options) Template given in the ipfixTemplateId specified in
        the ipfixTemplateTable."
    ::= { ipfixMainObjects 3 }

ipfixTemplateDefinitionEntry OBJECT-TYPE
    SYNTAX      IpfixTemplateDefinitionEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Defines an entry in the ipfixTemplateDefinitionTable."
    INDEX       {
        ipfixTransportSessionIndex,
        ipfixTemplateObservationDomainId,
        ipfixTemplateId,
        ipfixTemplateDefinitionIndex
    }
    ::= { ipfixTemplateDefinitionTable 1 }

IpfixTemplateDefinitionEntry ::=
    SEQUENCE {
        ipfixTemplateDefinitionIndex            Unsigned32,
        ipfixTemplateDefinitionIeId             Unsigned32,
        ipfixTemplateDefinitionIeLength         Unsigned32,
        ipfixTemplateDefinitionEnterpriseNumber Unsigned32,
        ipfixTemplateDefinitionFlags            BITS
    }

ipfixTemplateDefinitionIndex OBJECT-TYPE
    SYNTAX      Unsigned32 (1..65535)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The ipfixTemplateDefinitionIndex specifies the order in
        which the Information Elements are used in the (Options)
        Template Record.

        Since a Template Record can contain a maximum of 65535
        Information Elements, the index is limited to this value."
    REFERENCE
        "RFC 5101, Specification of the IP Flow Information Export
        (IPFIX) Protocol for the Exchange of IP Traffic Flow
        Information, Sections 3.4.1 and 3.4.2."
    ::= { ipfixTemplateDefinitionEntry 1 }

ipfixTemplateDefinitionIeId OBJECT-TYPE
    SYNTAX      Unsigned32 (1..65535)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This indicates the Information Element Id at position
        ipfixTemplateDefinitionIndex in the (Options) Template
        ipfixTemplateId.  This implicitly specifies the data type
        of the Information Element.  The elements are registered
        at IANA.  A current list of assignments can be found at
        <http://www.iana.org/assignments/ipfix>"
    REFERENCE
        "RFC 5101, Specification of the IP Flow Information Export
        (IPFIX) Protocol for the Exchange of IP Traffic Flow
        Information, Section 3.2.

        RFC 5102, Information Model for IP Flow Information Export."
    ::= { ipfixTemplateDefinitionEntry 2 }

ipfixTemplateDefinitionIeLength OBJECT-TYPE
    SYNTAX      Unsigned32 (0..65535)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This indicates the length of the Information Element Id at
        position ipfixTemplateDefinitionIndex in the (Options)
        Template ipfixTemplateId."
    REFERENCE
        "RFC 5101, Specification of the IP Flow Information Export
        (IPFIX) Protocol for the Exchange of IP Traffic Flow
        Information, Section 3.2.

        RFC 5102, Information Model for IP Flow Information Export."
    ::= { ipfixTemplateDefinitionEntry 3 }

ipfixTemplateDefinitionEnterpriseNumber OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "IANA enterprise number of the authority defining the
        Information Element identifier in this Template Record.
        Enterprise numbers are assigned by IANA.  A current list of
        all assignments is available from
        <http://www.iana.org/assignments/enterprise-numbers/>.

        This object must be zero(0) for all standard Information
        Elements registered with IANA.  A current list of these
        elements is available from
        <http://www.iana.org/assignments/ipfix/ipfix.xhtml>."
    REFERENCE
        "RFC 5101, Specification of the IP Flow Information Export
        (IPFIX) Protocol for the Exchange of IP Traffic Flow
        Information, Section 3.2.

        RFC 5102, Information Model for IP Flow Information Export."
    ::= { ipfixTemplateDefinitionEntry 4 }

ipfixTemplateDefinitionFlags OBJECT-TYPE
    SYNTAX      BITS {
                    scope(0),
                    flowKey(1)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This bitmask indicates special attributes for the
        Information Element:

        scope(0)
            This Information Element is used for scope.

        flowKey(1)
            This Information Element is a Flow Key.

        Thus, we get the following values for an Information Element:

        If neither bit scope(0) nor bit flowKey(1) are set
            The Information Element is neither used for scoping nor
            as Flow Key.
        If only bit scope(0) is set
            The Information Element is used for scoping.
        If only bit flowKey(1) is set
            The Information Element is used as Flow Key.

        Both bit scope(0) and flowKey(1) MUST NOT be set at the same
        time.  This combination is not allowed."
    REFERENCE
        "RFC 5101, Specification of the IP Flow Information
        Export (IPFIX) Protocol for the Exchange of IP Traffic Flow
        Information, Sections 2 and 3.4.2.1.

        RFC 5102, Information Model for IP Flow Information Export."
    ::= { ipfixTemplateDefinitionEntry 5 }

--------------------------------------------------------------------
-- 1.1.4: Export Table
--------------------------------------------------------------------
ipfixExportTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF IpfixExportEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table lists all exports of an IPFIX device.

        On Exporters, this table contains all exports grouped by
        Transport Session, Observation Domain Id, Template Id, and
        Metering Process represented by the
        ipfixMeteringProcessCacheId.  Thanks to the ipfixExportIndex,
        the exports can group one or more Transport Sessions to
        achieve a special functionality like failover management,
        load-balancing, etc.  The entries with the same
        ipfixExportIndex, ipfixObservationDomainId,
        and ipfixMeteringProcessCacheId define a Transport
        Session group.  If the Exporter does not use Transport
        Session grouping, then each ipfixExportIndex contains a
        single ipfixMeteringProcessCacheId and thus a singe
        Transport Session, and this session MUST have the member
        type primary(1).  Transport Sessions referenced in this
        table MUST have the ipfixTransportSessionDeviceMode
        exporting(1).

        On Collectors, this table is not needed."
    ::= { ipfixMainObjects 4 }

ipfixExportEntry OBJECT-TYPE
    SYNTAX      IpfixExportEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Defines an entry in the ipfixExportTable."
    INDEX       {
        ipfixExportIndex,
        ipfixMeteringProcessCacheId,
        ipfixTransportSessionIndex
    }
    ::= { ipfixExportTable 1 }

IpfixExportEntry ::=
    SEQUENCE {
       ipfixExportIndex      Unsigned32,
       ipfixExportMemberType INTEGER
    }

ipfixExportIndex OBJECT-TYPE
    SYNTAX      Unsigned32 (1..4294967295)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Locally arbitrary, but unique identifier of an entry in
        the ipfixExportTable.  The value is expected
        to remain constant from a re-initialization of the entity's
        network management agent to the next re-initialization.

        A common ipfixExportIndex between two entries from this
        table expresses that there is a relationship between the
        Transport Sessions in ipfixTransportSessionIndex.  The type
        of relationship is expressed by the value of
        ipfixExportMemberType."
    ::= { ipfixExportEntry 1 }

ipfixExportMemberType OBJECT-TYPE
    SYNTAX      INTEGER {
                    unknown(0),
                    primary(1),
                    secondary(2),
                    parallel(3),
                    loadBalancing(4)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The type of a member Transport Session in a Transport
        Session group (identified by the value of ipfixExportIndex,
        ipfixObservationDomainId, and ipfixMeteringProcessCacheId).
        The following values are valid:

        unknown(0)
            This value MUST be used if the status of the group
            membership cannot be detected by the equipment.  This
            value should be avoided as far as possible.

        primary(1)
            This value is used for a group member that is used as
            the primary target of an Exporter.  Other group members
            (with the same ipfixExportIndex and
            ipfixMeteringProcessCacheId) MUST NOT have the value
            primary(1) but MUST have the value secondary(2).
            This value MUST also be specified if the Exporter does
            not support Transport Session grouping.  In this case,
            the group contains only one Transport Session.

        secondary(2)
            This value is used for a group member that is used as a
            secondary target of an Exporter.  The Exporter will use
            one of the targets specified as secondary(2) within the
            same Transport Session group when the primary target is
            not reachable.

        parallel(3)
            This value is used for a group member that is used for
            duplicate exporting, i.e., all group members identified
            by the ipfixExportIndex are exporting the same Records
            in parallel.  This implies that all group members MUST
            have the same membertype parallel(3).

        loadBalancing(4)
            This value is used for a group member that is used
            as one target for load-balancing.  This means that a
            Record is sent to one of the group members in this
            group identified by ipfixExportIndex.
            This implies that all group members MUST have the same
            membertype loadBalancing(4)."
    ::= { ipfixExportEntry 2 }

--------------------------------------------------------------------
-- 1.1.5: Metering Process Table
--------------------------------------------------------------------
ipfixMeteringProcessTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF IpfixMeteringProcessEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table lists so-called caches used at the Metering
        Process to store the metering data of Flows observed at
        the Observation Points given in the
        ipfixObservationPointGroupReference.  The table lists the
        timeouts that specify when the cached metering data is
        expired.

        On Collectors, the table is not needed."
    ::= { ipfixMainObjects 5 }

ipfixMeteringProcessEntry OBJECT-TYPE
    SYNTAX      IpfixMeteringProcessEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Defines an entry in the ipfixMeteringProcessTable."
    INDEX       { ipfixMeteringProcessCacheId }
    ::= { ipfixMeteringProcessTable 1 }

IpfixMeteringProcessEntry ::=
    SEQUENCE {
        ipfixMeteringProcessCacheId              Unsigned32,
        ipfixMeteringProcessObservationPointGroupRef Unsigned32,
        ipfixMeteringProcessCacheActiveTimeout   Unsigned32,
        ipfixMeteringProcessCacheInactiveTimeout Unsigned32
    }

ipfixMeteringProcessCacheId OBJECT-TYPE
    SYNTAX      Unsigned32 (1..4294967295)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Locally arbitrary, but unique identifier of an entry in the
        ipfixMeterinProcessTable.  The value is expected to remain
        constant from a re-initialization of the entity's network
        management agent to the next re-initialization."
    ::= { ipfixMeteringProcessEntry 1 }

ipfixMeteringProcessObservationPointGroupRef OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The Observation Point Group Id that links this table entry
        to the ipfixObservationPointTable.  The matching
        ipfixObservationPointGroupId in that table gives the
        Observation Points used in that cache.  If the Observation
        Points are unknown, the
        ipfixMeteringProcessObservationPointGroupRef MUST be zero."
    ::= { ipfixMeteringProcessEntry 2 }

ipfixMeteringProcessCacheActiveTimeout OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "On the Exporter, this object contains the time after which a
        Flow is expired (and a Data Record for the template is sent)
        even though packets matching this Flow are still received by
        the Metering Process.  If this value is 0, the Flow is not
        prematurely expired."
    REFERENCE
        "RFC 5470, Architecture for IP Flow Information Export,
        Section 5.1.1, item 3."
    ::= { ipfixMeteringProcessEntry 3 }

ipfixMeteringProcessCacheInactiveTimeout OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "seconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "On the Exporter. this object contains the time after which a
        Flow is expired (and a Data Record for the template is sent)
        when no packets matching this Flow are received by the
        Metering Process for the given number of seconds.  If this
        value is zero, the Flow is expired immediately, i.e., a Data
        Record is sent for every packet received by the Metering
        Process."
    REFERENCE
        "RFC 5470, Architecture for IP Flow Information Export,
        Section 5.1.1, item 1"
    ::= { ipfixMeteringProcessEntry 4 }

--------------------------------------------------------------------
-- 1.1.6: Observation Point Table
--------------------------------------------------------------------
ipfixObservationPointTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF IpfixObservationPointEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table lists the Observation Points used within an
        Exporter by the Metering Process. The index
        ipfixObservationPointGroupId groups Observation Points
        and is referenced in the Metering Process table.

        On Collectors this table is not needed."
    ::= { ipfixMainObjects 6 }

ipfixObservationPointEntry OBJECT-TYPE
    SYNTAX      IpfixObservationPointEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Defines an entry in the ipfixObservationPointTable."
    INDEX       {
        ipfixObservationPointGroupId,
        ipfixObservationPointIndex
    }
    ::= { ipfixObservationPointTable 1 }

IpfixObservationPointEntry ::=
    SEQUENCE {
        ipfixObservationPointGroupId           Unsigned32,
        ipfixObservationPointIndex             Unsigned32,
        ipfixObservationPointObservationDomainId Unsigned32,
        ipfixObservationPointPhysicalEntity    PhysicalIndexOrZero,
        ipfixObservationPointPhysicalInterface InterfaceIndexOrZero,
        ipfixObservationPointPhysicalEntityDirection INTEGER
    }

ipfixObservationPointGroupId OBJECT-TYPE
    SYNTAX      Unsigned32 (1..4294967295)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Locally arbitrary, but unique identifier of an entry in the
        ipfixObservationPointTable.  The value is expected to remain
        constant from a re-initialization of the entity's network
        management agent to the next re-initialization.

        This index represents a group of Observation Points.

        The special value of 0 MUST NOT be used within this table
        but is reserved for the usage in the
        ipfixMeteringProcessTable.  An index of 0 for the
        ipfixObservationPointGroupReference index in that table
        indicates that an Observation Point is unknown or
        unspecified for a Metering Process cache."
    ::= { ipfixObservationPointEntry 1 }

ipfixObservationPointIndex OBJECT-TYPE
    SYNTAX      Unsigned32 (1..4294967295)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Locally arbitrary, but unique identifier of an entry in the
        ipfixObservationPointTable.  The value is expected to remain
        constant from a re-initialization of the entity's network
        management agent to the next re-initialization.

        This index represents a single Observation Point in an
        Observation Point group."
    ::= { ipfixObservationPointEntry 2 }

ipfixObservationPointObservationDomainId OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The Id of the Observation Domain in which this
        Observation Point is included.

        The special value of 0 indicates that the Observation
        Points within this group cannot be applied to a single
        Observation Domain."
    REFERENCE
        "RFC 5101, Specification of the IP Flow Information Export
        (IPFIX) Protocol for the Exchange of IP
        Traffic Flow Information, Section 3.1."
    ::= { ipfixObservationPointEntry 3 }

ipfixObservationPointPhysicalEntity OBJECT-TYPE
    SYNTAX      PhysicalIndexOrZero
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object contains the index of a physical entity in
        the ENTITY MIB.  This physical entity is the given
        Observation Point.  If such a physical entity cannot be
        specified or is not known, then the object is zero."
    ::= { ipfixObservationPointEntry 4 }

ipfixObservationPointPhysicalInterface OBJECT-TYPE
    SYNTAX      InterfaceIndexOrZero
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object contains the index of a physical interface in
        the IF MIB.  This physical interface is the given
        Observation Point.  If such a physical interface cannot be
        specified or is not known, then the object is zero.

        This object MAY be used stand alone or in addition to
        ipfixObservationPointPhysicalEntity.  If
        ipfixObservationPointPhysicalEntity is not zero, this object
        MUST point to the same physical interface that is
        referenced in ipfixObservationPointPhysicalEntity.
        Otherwise, it may reference any interface in the IF MIB."
    ::= { ipfixObservationPointEntry 5 }

ipfixObservationPointPhysicalEntityDirection OBJECT-TYPE
    SYNTAX      INTEGER {
                    unknown(0),
                    ingress(1),
                    egress(2),
                    both(3)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The direction of the Flow that is monitored on the given
        physical entity.  The following values are valid:

        unknown(0)
            This value MUST be used if a direction is not
            known for the given physical entity.

        ingress(1)
            This value is used for monitoring incoming Flows on the
            given physical entity.

        egress(2)
            This value is used for monitoring outgoing Flows on the
            given physical entity.

        both(3)
            This value is used for monitoring incoming and outgoing
            Flows on the given physical entity."
    ::= { ipfixObservationPointEntry 6 }

--------------------------------------------------------------------
-- 1.1.7: Selection Process Table
--------------------------------------------------------------------
ipfixSelectionProcessTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF IpfixSelectionProcessEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains Selector Functions connected to a
        Metering Process by the index ipfixMeteringProcessCacheId.
        The Selector Functions are grouped into Selection Processes
        by the ipfixSelectionProcessIndex.  The Selector Functions
        are applied within the Selection Process to the packets
        observed for the given Metering Process cache in increasing
        order implied by the ipfixSelectionProcessSelectorIndex.
        This means Selector Functions with lower
        ipfixSelectionProcessSelectorIndex are applied first.  The
        remaining packets are accounted for in Flow Records.

        Since IPFIX does not define any Selector Function (except
        selecting every packet), this is a placeholder for future
        use and a guideline for implementing enterprise-specific
        Selector Function objects.

        The following object tree should visualize how the
        Selector Function objects should be implemented:

        ipfixSelectorFunctions
        |
        +- ipfixFuncSelectAll
        |  |
        |  +- ipfixFuncSelectAllAvail (is the function available?)
        |
        +- ipfixFuncF2
        |  |
        |  +- ipfixFuncF2Avail (is the function F2 available?)
        |  |
        |  +- ipfixFuncF2Parameters (a table with parameters)
        ...
        |
        +- ipfixFunFn...

        If a Selector Function takes parameters, the MIB should
        contain a table with an entry for each set of parameters
        used at the Exporter."
    ::= { ipfixMainObjects 7 }

ipfixSelectionProcessEntry OBJECT-TYPE
    SYNTAX      IpfixSelectionProcessEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Defines an entry in the ipfixSelectionProcessTable."
    INDEX       {
        ipfixMeteringProcessCacheId,
        ipfixSelectionProcessIndex,
        ipfixSelectionProcessSelectorIndex
    }
    ::= { ipfixSelectionProcessTable 1 }

IpfixSelectionProcessEntry ::= SEQUENCE {
        ipfixSelectionProcessIndex            Unsigned32,
        ipfixSelectionProcessSelectorIndex    Unsigned32,
        ipfixSelectionProcessSelectorFunction OBJECT IDENTIFIER
    }

ipfixSelectionProcessIndex OBJECT-TYPE
    SYNTAX      Unsigned32 (1..4294967295)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Locally arbitrary, but unique identifier of an entry in the
        ipfixSelectionProcessTable.  The value is expected to remain
        constant from a re-initialization of the entity's network
        management agent to the next re-initialization."
    ::= { ipfixSelectionProcessEntry 1 }

ipfixSelectionProcessSelectorIndex OBJECT-TYPE
    SYNTAX      Unsigned32 (1..4294967295)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Index specifying the order in which the referenced
        ipfixSelctionProcessSelectorFunctions are applied to the
        observed packet stream within the given Selection Process
        (identified by the ipfixSelectionProcessIndex).  The
        Selector Functions are applied in increasing order, i.e.,
        Selector Functions with lower index are applied first."
    ::= { ipfixSelectionProcessEntry 2 }

ipfixSelectionProcessSelectorFunction OBJECT-TYPE
    SYNTAX      OBJECT IDENTIFIER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The pointer to the Selector Function used at position
        ipfixSelectionProcessSelectorIndex in the list of Selector
        Functions for the Metering Process cache specified by the
        index ipfixMeteringProcessCacheId and for the given
        Selection Process (identified by the
        ipfixSelectionProcessIndex).

        This usually points to an object in the IPFIX SELECTOR MIB.
        If the Selector Function does not take parameters, then it
        MUST point to the root of the function subtree.  If the
        function takes parameters, then it MUST point to an entry
        in the parameter table of the Selector Function."
    ::= { ipfixSelectionProcessEntry 3 }

--------------------------------------------------------------------
-- 1.2.1: Transport Session Statistics Table
--------------------------------------------------------------------
ipfixTransportSessionStatsTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF IpfixTransportSessionStatsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table lists Transport Sessions statistics between
        Exporting Processes and Collecting Processes."
    ::= { ipfixStatistics 1 }

ipfixTransportSessionStatsEntry OBJECT-TYPE
    SYNTAX      IpfixTransportSessionStatsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Defines an entry in the ipfixTransportSessionStatsTable."
    AUGMENTS    { ipfixTransportSessionEntry }
    ::= { ipfixTransportSessionStatsTable 1 }

IpfixTransportSessionStatsEntry ::=
    SEQUENCE {
        ipfixTransportSessionRate              Gauge32,
        ipfixTransportSessionPackets           Counter64,
        ipfixTransportSessionBytes             Counter64,
        ipfixTransportSessionMessages          Counter64,
        ipfixTransportSessionDiscardedMessages Counter64,
        ipfixTransportSessionRecords           Counter64,
        ipfixTransportSessionTemplates         Counter64,
        ipfixTransportSessionOptionsTemplates  Counter64,
        ipfixTransportSessionDiscontinuityTime TimeStamp
    }

ipfixTransportSessionRate OBJECT-TYPE
    SYNTAX      Gauge32
    UNITS       "bytes/second"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of bytes per second received by the
        Collector or transmitted by the Exporter.  A
        value of zero (0) means that no packets were sent or
        received, yet.  This object is updated every second."
    ::= { ipfixTransportSessionStatsEntry 1 }

ipfixTransportSessionPackets OBJECT-TYPE
    SYNTAX      Counter64
    UNITS       "packets"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of packets received by the Collector
        or transmitted by the Exporter.
        Discontinuities in the value of this counter can occur at
        re-initialization of the management system and at other
        times as indicated by the value of
        ipfixTransportSessionDiscontinuityTime."
    ::= { ipfixTransportSessionStatsEntry 2 }

ipfixTransportSessionBytes OBJECT-TYPE
    SYNTAX      Counter64
    UNITS       "bytes"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of bytes received by the Collector
        or transmitted by the Exporter.
        Discontinuities in the value of this counter can occur at
        re-initialization of the management system and at other
        times as indicated by the value of
        ipfixTransportSessionDiscontinuityTime."
    ::= { ipfixTransportSessionStatsEntry 3 }

ipfixTransportSessionMessages OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of IPFIX Messages received by the
        Collector or transmitted by the Exporter.
        Discontinuities in the value of this counter can occur at
        re-initialization of the management system and at other
        times as indicated by the value of
        ipfixTransportSessionDiscontinuityTime."
    ::= { ipfixTransportSessionStatsEntry 4 }

ipfixTransportSessionDiscardedMessages OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of received IPFIX Message that are malformed,
        cannot be decoded, are received in the wrong order, or are
        missing according to the sequence number.

        If used at the Exporter, the number of messages that could
        not be sent due to, e.g., internal buffer overflows, network
        congestion, or routing issues.
        Discontinuities in the value of this counter can occur at
        re-initialization of the management system and at other
        times as indicated by the value of
        ipfixTransportSessionDiscontinuityTime."
    ::= { ipfixTransportSessionStatsEntry 5 }

ipfixTransportSessionRecords OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of Data Records received by the Collector or
        transmitted by the Exporter.
        Discontinuities in the value of this counter can occur at
        re-initialization of the management system and at other
        times as indicated by the value of
        ipfixTransportSessionDiscontinuityTime."
    ::= { ipfixTransportSessionStatsEntry 6 }

ipfixTransportSessionTemplates OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of Templates received or transmitted.
        Discontinuities in the value of this counter can occur at
        re-initialization of the management system and at other
        times as indicated by the value of
        ipfixTransportSessionDiscontinuityTime."
    ::= { ipfixTransportSessionStatsEntry 7 }

ipfixTransportSessionOptionsTemplates OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of Options Templates received or transmitted.
        Discontinuities in the value of this counter can occur at
        re-initialization of the management system and at other
        times as indicated by the value of
        ipfixTransportSessionDiscontinuityTime."
    ::= { ipfixTransportSessionStatsEntry 8 }

ipfixTransportSessionDiscontinuityTime OBJECT-TYPE
    SYNTAX       TimeStamp
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
        "The value of sysUpTime at the most recent occasion at which
        one or more of the Transport Session counters suffered a
        discontinuity.
        A value of zero indicates no such discontinuity has
        occurred since the last re-initialization of the local
        management subsystem."
    ::= { ipfixTransportSessionStatsEntry 9 }

--------------------------------------------------------------------
-- 1.2.2: Template Statistics Table
--------------------------------------------------------------------
ipfixTemplateStatsTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF IpfixTemplateStatsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table lists statistics objects per Template."
    ::= { ipfixStatistics 2 }

ipfixTemplateStatsEntry OBJECT-TYPE
    SYNTAX      IpfixTemplateStatsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Defines an entry in the ipfixTemplateStatsTable."
    AUGMENTS    { ipfixTemplateEntry }
    ::= { ipfixTemplateStatsTable 1 }

IpfixTemplateStatsEntry ::=
    SEQUENCE {
        ipfixTemplateDataRecords       Counter64,
        ipfixTemplateDiscontinuityTime TimeStamp
    }

ipfixTemplateDataRecords OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of Data Records that are transmitted or received
        per Template.
        Discontinuities in the value of this counter can occur at
        re-initialization of the management system, and at other
        times as indicated by the value of
        ipfixTemplateDiscontinuityTime."
    ::= { ipfixTemplateStatsEntry 1 }

ipfixTemplateDiscontinuityTime OBJECT-TYPE
    SYNTAX       TimeStamp
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
        "The value of sysUpTime at the most recent occasion at which
        the Template counter suffered a discontinuity.
        A value of zero indicates no such discontinuity has
        occurred since the last re-initialization of the local
        management subsystem."
    ::= { ipfixTemplateStatsEntry 2 }

--------------------------------------------------------------------
-- 1.2.3: Metering Process Statistics Table
--------------------------------------------------------------------
ipfixMeteringProcessStatsTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF IpfixMeteringProcessStatsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table lists statistic objects that have data per
        Metering Process cache.

        On Collectors, this table is not needed."
    ::= { ipfixStatistics 3 }

ipfixMeteringProcessStatsEntry OBJECT-TYPE
    SYNTAX      IpfixMeteringProcessStatsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Defines an entry in the ipfixMeteringProcessStatsTable."
    AUGMENTS    { ipfixMeteringProcessEntry }
    ::= { ipfixMeteringProcessStatsTable 1 }

IpfixMeteringProcessStatsEntry ::=
    SEQUENCE {
        ipfixMeteringProcessCacheActiveFlows          Gauge32,
        ipfixMeteringProcessCacheUnusedCacheEntries   Gauge32,
        ipfixMeteringProcessCacheDataRecords          Counter64,
        ipfixMeteringProcessCacheDiscontinuityTime    TimeStamp
    }

ipfixMeteringProcessCacheActiveFlows OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of Flows currently active at this cache."
    ::= { ipfixMeteringProcessStatsEntry 1 }

ipfixMeteringProcessCacheUnusedCacheEntries   OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of unused cache entries."
    ::= { ipfixMeteringProcessStatsEntry 2 }

ipfixMeteringProcessCacheDataRecords OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of Data Records generated.
        Discontinuities in the value of this counter can occur at
        re-initialization of the management system and at other
        times as indicated by the value of
        ipfixTemplateDiscontinuityTime."
    ::= { ipfixMeteringProcessStatsEntry 3 }

ipfixMeteringProcessCacheDiscontinuityTime OBJECT-TYPE
    SYNTAX       TimeStamp
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
        "The value of sysUpTime at the most recent occasion at which
        the Metering Process counter suffered a discontinuity.
        A value of zero indicates no such discontinuity has
        occurred since the last re-initialization of the local
        management subsystem."
    ::= { ipfixMeteringProcessStatsEntry 4 }

--------------------------------------------------------------------
-- 1.2.4: Selection Process Statistics Table
--------------------------------------------------------------------
ipfixSelectionProcessStatsTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF IpfixSelectionProcessStatsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains statistics for the Selector Functions
        connected to Metering Process by the index
        ipfixMeteringProcessCacheId.

        The indexes MUST match an entry in the
        ipfixSelectionProcessTable."
    ::= { ipfixStatistics 4 }

ipfixSelectionProcessStatsEntry OBJECT-TYPE
    SYNTAX      IpfixSelectionProcessStatsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Defines an entry in the ipfixSelectionProcessStatsTable."
    AUGMENTS    { ipfixSelectionProcessEntry }
    ::= { ipfixSelectionProcessStatsTable 1 }

IpfixSelectionProcessStatsEntry ::= SEQUENCE {
        ipfixSelectionProcessStatsPacketsObserved   Counter64,
        ipfixSelectionProcessStatsPacketsDropped    Counter64,
        ipfixSelectionProcessStatsDiscontinuityTime TimeStamp
    }

ipfixSelectionProcessStatsPacketsObserved OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of packets observed at the entry point of the
        function.  The entry point may be the Observation Point or
        the exit point of another Selector Function.
        Discontinuities in the value of this counter can occur at
        re-initialization of the management system and at other
        times as indicated by the value of
        ipfixSelectionProcessStatsDiscontinuityTime."
    ::= { ipfixSelectionProcessStatsEntry 1 }

ipfixSelectionProcessStatsPacketsDropped OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of packets dropped while selecting packets.
        Discontinuities in the value of this counter can occur at
        re-initialization of the management system and at other
        times as indicated by the value of
        ipfixSelectionProcessStatsDiscontinuityTime."
    ::= { ipfixSelectionProcessStatsEntry 2 }

ipfixSelectionProcessStatsDiscontinuityTime OBJECT-TYPE
    SYNTAX       TimeStamp
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
        "The value of sysUpTime at the most recent occasion at which
        one or more of the Selector counters suffered a
        discontinuity.
        A value of zero indicates no such discontinuity has
        occurred since the last re-initialization of the local
        management subsystem."
    ::= { ipfixSelectionProcessStatsEntry 3 }

--==================================================================
-- 2: Conformance Information
--==================================================================
ipfixCompliances OBJECT IDENTIFIER ::= { ipfixConformance 1 }
ipfixGroups      OBJECT IDENTIFIER ::= { ipfixConformance 2 }

--------------------------------------------------------------------
-- 2.1: Compliance Statements
--------------------------------------------------------------------
ipfixCollectorCompliance MODULE-COMPLIANCE
    STATUS      current
    DESCRIPTION
        "An implementation that builds an IPFIX Collector
        that complies to this module MUST implement the objects
        defined in the mandatory group ipfixCommonGroup.

        The implementation of all objects in the other groups is
        optional and depends on the corresponding functionality
        implemented in the equipment.

        An implementation that is compliant to this MIB module
        is limited to use only the values TCP (6), UDP (17), and
        SCTP (132) in the ipfixTransportSessionProtocol object
        because these are the only protocol currently specified
        for usage within IPFIX (see RFC 5101)."
    MODULE  -- this module
    MANDATORY-GROUPS {
        ipfixCommonGroup
    }

    GROUP ipfixCommonStatsGroup
    DESCRIPTION
        "These objects should be implemented if the statistics
        function is implemented in the equipment."
    ::= { ipfixCompliances 1 }

ipfixExporterCompliance MODULE-COMPLIANCE
    STATUS  current
    DESCRIPTION
        "An implementation that builds an IPFIX Exporter that
        complies to this module MUST implement the objects defined
        in the mandatory group ipfixCommonGroup.  The implementation
        of all other objects depends on the implementation of the
        corresponding functionality in the equipment."
    MODULE  -- this module

    MANDATORY-GROUPS {
            ipfixCommonGroup,
            ipfixExporterGroup
    }

    GROUP ipfixCommonStatsGroup
    DESCRIPTION
        "These objects should be implemented if the statistics
        function is implemented in the equipment."

    GROUP ipfixExporterStatsGroup
    DESCRIPTION
        "These objects MUST be implemented if statistical functions
        are implemented on the equipment."
    ::= { ipfixCompliances 2 }

--------------------------------------------------------------------
-- 2.2: MIB Grouping
--------------------------------------------------------------------
ipfixCommonGroup OBJECT-GROUP
    OBJECTS {
        ipfixTransportSessionProtocol,
        ipfixTransportSessionSourceAddressType,
        ipfixTransportSessionSourceAddress,
        ipfixTransportSessionDestinationAddressType,
        ipfixTransportSessionDestinationAddress,
        ipfixTransportSessionSourcePort,
        ipfixTransportSessionDestinationPort,
        ipfixTransportSessionSctpAssocId,
        ipfixTransportSessionDeviceMode,
        ipfixTransportSessionTemplateRefreshTimeout,
        ipfixTransportSessionOptionsTemplateRefreshTimeout,
        ipfixTransportSessionTemplateRefreshPacket,
        ipfixTransportSessionOptionsTemplateRefreshPacket,
        ipfixTransportSessionIpfixVersion,
        ipfixTransportSessionStatus,
        ipfixTemplateSetId,
        ipfixTemplateAccessTime,
        ipfixTemplateDefinitionIeId,
        ipfixTemplateDefinitionIeLength,
        ipfixTemplateDefinitionEnterpriseNumber,
        ipfixTemplateDefinitionFlags
    }
    STATUS      current
    DESCRIPTION
        "The main IPFIX objects."
    ::= { ipfixGroups 1 }

ipfixCommonStatsGroup OBJECT-GROUP
    OBJECTS {
        ipfixTransportSessionRate,
        ipfixTransportSessionPackets,
        ipfixTransportSessionBytes,
        ipfixTransportSessionMessages,
        ipfixTransportSessionDiscardedMessages,
        ipfixTransportSessionRecords,
        ipfixTransportSessionTemplates,
        ipfixTransportSessionOptionsTemplates,
        ipfixTransportSessionDiscontinuityTime,
        ipfixTemplateDataRecords,
        ipfixTemplateDiscontinuityTime
    }
    STATUS      current
    DESCRIPTION
        "Common statistical objects."
    ::= { ipfixGroups 2 }

ipfixExporterGroup OBJECT-GROUP
    OBJECTS {
        ipfixExportMemberType,
        ipfixMeteringProcessObservationPointGroupRef,
        ipfixMeteringProcessCacheActiveTimeout,
        ipfixMeteringProcessCacheInactiveTimeout,
        ipfixObservationPointObservationDomainId,
        ipfixObservationPointPhysicalEntity,
        ipfixObservationPointPhysicalInterface,
        ipfixObservationPointPhysicalEntityDirection,
        ipfixSelectionProcessSelectorFunction
    }
    STATUS      current
    DESCRIPTION
        "The main objects for Exporters."
    ::= { ipfixGroups 3 }

ipfixExporterStatsGroup OBJECT-GROUP
    OBJECTS {
        ipfixMeteringProcessCacheActiveFlows,
        ipfixMeteringProcessCacheUnusedCacheEntries,
        ipfixMeteringProcessCacheDataRecords,
        ipfixMeteringProcessCacheDiscontinuityTime,
        ipfixSelectionProcessStatsPacketsObserved,
        ipfixSelectionProcessStatsPacketsDropped,
        ipfixSelectionProcessStatsDiscontinuityTime
    }
    STATUS      current
    DESCRIPTION
        "The statistical objects for Exporters."
    ::= { ipfixGroups 4 }